Security Perth Agility 3 Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Sistemas de segurança - controlo de acesso Security Perth Agility 3. Security Perth Agility 3 User manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir

Resumo do Conteúdo

Página 1 - 9313 1881

User Manual 9313 1881

Página 2

Agility 3 User Manual Page 10 Status Button / Service Call (Listen & Talk) The button on the main unit can be defined as a system status indicator

Página 3

Agility 3 User Manual Page 11 Sound Indications In addition to the visual indications provided by the Agility’s LEDs, your system produces audible not

Página 4

Agility 3 User Manual Page 12 Chapter 2 - Local System Operation 2.1 Arming your system Arming your system causes the intrusion detectors to trigger

Página 5 - Chapter 1 - Introduction

Agility 3 User Manual Page 13 Click Full Arm Stay (Home) arming: Stay arming activates only perimeter detectors (as defined by your installer), enabli

Página 6

Agility 3 User Manual Page 14 To arm using Partition arming (Away or Stay) procedure Quick mode: / / > / High security mode: / / >

Página 7

Agility 3 User Manual Page 15 2.2 Disarming your system Disarming your system causes the detectors not to trigger an alarm when violated. When you ent

Página 8

Agility 3 User Manual Page 16 Enter your user code and click DISARM Partition disarming: Partition disarming enables you to disarm individual partitio

Página 9

Agility 3 User Manual Page 17 Disarming after an alarm: When silencing an alarm the system goes into a disarm state. After the system is disarmed the

Página 10 - Agility 3 User Manual

Agility 3 User Manual Page 18 Installer Reset Your monitoring station (MS) or installer can reset your system remotely or locally from the keypad. To

Página 11

Agility 3 User Manual Page 19 2.3 Sending a Panic Alarm Panic alarms enable you to send a message to the monitoring station in the event of an emergen

Página 12 - Quick mode:

Agility 3 User Manual Page 2 Important Notice This guide is delivered subject to the following conditions and restrictions: This guide contains propri

Página 13

Agility 3 User Manual Page 20 Chapter 3 - Remote System Operation 3.1 Remote Phone Operation The Agility enables you to operate the system from a rem

Página 14

Agility 3 User Manual Page 21 Operation Quick Key Combination Changing Zone Bypass status Press [3] followed by the zone number and then [#][9] Operat

Página 15

Agility 3 User Manual Page 22 Notes: If no voice is detected, the event message will start playing 5 seconds after phone pick up. Press [#] to begin p

Página 16

Agility 3 User Manual Page 23 To listen in or talk: 1. From the Operations/Acknowledge menu, press [6]. The following messages areannounced:“To Listen

Página 17

Agility 3 User Manual Page 24 Operation SMS Message Structure Example partition Disarm by Partition [Code] D [Partition No.] 1234D1 Bypass a zone [Co

Página 18

Agility 3 User Manual Page 25 Self registration To enable the use of the iRISCO App, register your panel to the RISCO cloud. Note: If using GPRS verif

Página 19

Agility 3 User Manual Page 26 Chapter 4 - User Functions and Settings The functions and settings explained in this chapter can only be performed via y

Página 20

Agility 3 User Manual Page 27 Setting / Changing User Codes The user assigned the Grand Master authority level can change all user codes but cannot vi

Página 21

Agility 3 User Manual Page 28 4. The display will show: "Delete Code. Are you sure?". Use the key to select [Y] and press . If successful,

Página 22

Agility 3 User Manual Page 29 Deleting a proximity tag Deleting proximity tags can be done by in two options: By user number: Use this option to delet

Página 23

Agility 3 User Manual Page 3 Table of Contents User Manual ...

Página 24

Agility 3 User Manual Page 30 6. Enter the phone number, including the area code (if required) or an e-mailaddress, as requested on the screen and pre

Página 25

Agility 3 User Manual Page 31 5. Select the Scheduling program index number. Use the key to activate / deactivate and press .4.5 Macro keys Programm

Página 26

Agility 3 User Manual Page 32 Key Represents and 0 simultaneously Deletes your entry from the cursor position forward /Use to toggle between / ///

Página 27

Agility 3 User Manual Page 33 Operation Grand Master User Installer Main Buzzer On/Off: Used to control the main unit buzzer. √ √ √ Walk test: Used to

Página 28

Agility 3 User Manual Page 34 Operation Grand Master User Installer Advanced  Service Mode:: Used to silence an alarm initiated by any tamper for a S

Página 29

Agility 3 User Manual Page 35 Operation Grand Master User Installer Allows the display of any previously entered service information. (Name and phone)

Página 30

Agility 3 User Manual Page 36 Chapter 5 - System Specifications The following technical specifications are applicable for the Agility: Electrical Char

Página 31

Agility 3 User Manual Page 37 Chapter 6 - EN 50131 Compliance Compliance Statement Hereby, RISCO Group declares that the Agility series of central uni

Página 32

Agility 3 User Manual Page 38 Appendix A - Keypad User Operations The following section details the user operations from the 2-way LCD wireless keypad

Página 33

Agility 3 User Manual Page 39 Operation1Quick Operation High Security Mode Fire Alarm Press and hold simultaneously for 2 seconds Emergency/Medical

Página 34

Agility 3 User Manual Page 4 Chapter 4 - User Functions and Settings ... 264.1 User Codes...

Página 35

Agility 3 User Manual Page 40 Operation1Quick Operation High Security Mode Changing Keypad Language Press and hold simultaneously for 2 seconds. Se

Página 36

Agility 3 User Manual Page 41 Appendix B - Remote Control User Operations The following section details the user operations from the Agility 2-Way Rem

Página 37

Agility 3 User Manual Page 42 Code Status LED/Buzzer Indications After each transmission (indicated by a flashing Green LED) from the remote control,

Página 38

Agility 3 User Manual Page 43 Appendix C - Installer Event Log Messages Event Message Description Activate UO=xx UO XX activation Actv UO=xx KF=zz UO

Página 39

Agility 3 User Manual Page 44 Event Message Description Comm OK Siren=y Communication OK between the Agility and Siren Y Comm. OK GSM Communication O

Página 40

Agility 3 User Manual Page 45 Event Message Description * GSM: Module comm.Internal GSM/GPRS BUS module trouble * GSM:NET avail. GSM network is not av

Página 41

Agility 3 User Manual Page 46 Event Message Description * Ksw away:P=y Partition Y is armed by key switch * Ksw disarm:P=y Partition Y is disarmed by

Página 42

Agility 3 User Manual Page 47 Event Message Description Soak fail Z=xx Zone XX has failed in the soak test Special KP=y Special alarm from the from wi

Página 43

Agility 3 User Manual Page 48 Appendix D: Web User Application The Web User Application provides a full interface to your system from a PC, cellular p

Página 44

Agility 3 User Manual Page 49 Menu Bar Use the Menu Bar to access the application functionality as per the above diagram. The following options are a

Página 45

Agility 3 User Manual Page 5 Chapter 1 - Introduction Congratulations on your purchase of Agility 3- RISCO Group's Picture Perfect Wireless Secur

Página 46

Agility 3 User Manual Page 50 Workspace The workspace offers additional links to the following pages of the application, including: Users and Codes, H

Página 47

Agility 3 User Manual Page 51 User code management The Users and Codes page enables you to manage your system's users. The page displays a table

Página 48

Agility 3 User Manual Page 52 3. Choose the user type from the available options.4. Enter the new user's 4-digit passcode.5. Enter the new user&a

Página 49 - Page 49

Agility 3 User Manual Page 53 Master users can click a listing bottom displayed ADD NEW row to enable creation of a new user, similar to the process o

Página 50 - Home Button

Agility 3 User Manual Page 54 Zone Bypass On The Main Page menu, click SETTINGS then Zone Bypass to bypass specified zones in your home that you don&a

Página 51 - User code management

Agility 3 User Manual Page 55 Change Appearance On The Main Page menu, click SETTINGS then Change Appearance to change the color scheme of your accoun

Página 52

Agility 3 User Manual Page 56 Alerts The Alerts feature allows those people included in your contact list to be notified by email when certain events

Página 53 - Change Password

Agility 3 User Manual Page 57 Event Log History The History page displays a log of events that have occurred within your system. For each event you ca

Página 54 - Zone Bypass

Agility 3 User Manual Page 58 Video Verification Using the 2-way wireless video verification PIR detectors installed in your home, the Web Application

Página 55 - Change Appearance

Agility 3 User Manual Page 59 FCC Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to P

Página 56

Agility 3 User Manual Page 6 1.2 Agility Architecture Your Agility controls and monitors a variety of sensors, detectors, and contacts placed througho

Página 57 - Event Log History

Agility 3 User Manual Page 60 RISCO Group Limited Warranty RISCO Group and its subsidiaries and affiliates ("Seller") warrants its products

Página 58 - Home Automation

Agility 3 User Manual Page 7 1.3 User Operating Tools The Agility system can be operated using several devices, some of which have been designed as bi

Página 59

Agility 3 User Manual Page 8 SMS: If your system is equipped with a GSM/GPRS module it can provide information about the system such as event occurre

Página 60

Agility 3 User Manual Page 9 1.4 Status Indications LED Indicators The LED indicators provide typical system indications, as discussed below. Some ind

Comentários a estes Manuais